Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros







Base de dados
Intervalo de ano de publicação
1.
Arq. bras. oftalmol ; 78(5): 313-317, Sep.-Oct. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-761517

RESUMO

ABSTRACTPurpose:To report and compare the surgical, visual, and anatomical outcomes following treatment of dislocated intraocular lenses (IOLs).Methods:The medical records of 28 eyes of 28 patients were evaluated. Age, gender, pre-and postoperative best-corrected visual acuity (BCVA), surgical methods, and complications were recorded.Results:Pre-and postoperative BCVA ranged from counting fingers to 20/32 and from counting fingers to 20/25, respectively. Late-onset dislocations were the most frequently observed complication. The most frequent surgical method was IOL repositioning in 15 of 28 patients, followed by IOL exchange in 11 patients, and IOL removal in 2 patients. Only 1 patient required surgical re-intervention with IOL capture.Conclusions:Visual acuity improved following the use of either IOL repositioning or IOL exchange. No superiority of one method over the other was observed. In the present retrospective case series, management of dislocated IOLs with repositioning or exchange of the primary implant conferred comparable surgical and visual outcomes.


RESUMOObjetivo:Relatar e comparar as abordagens cirúrgicas e os resultados visuais e anatômicos no tratamento de lentes intraoculares (IOL) deslocadas.Métodos:Foram avaliados os registros médicos de 28 olhos de 28 pacientes. Idade, sexo, melhor acuidade visual corrigida pré e pós-operatória, abordagens cirúrgicas e complicações foram registrados.Resultados:Melhor acuidade visual corrigida pré e pós-operatória variou de conta dedos a 20/32 e de conta dedos a 20/25, respectivamente. Os deslocamentos tardios foram os mais frequentemente encontrados. A cirurgia mais frequente foi o reposicionamento da IOL em 15 dos 28 pacientes, em seguida, o troca da IOL em 11 pacientes, e a remoção da IOL em dois pacientes. Apenas um caso de necessitou de reintervenção devido à captura da IOL.Conclusões:A acuidade visual melhorou em ambas as abordagens, reposicionamento e troca de IOL. Não houve superioridade de um método sobre o outro. Na presente série de casos retrospectiva, o tratamento do deslocamento de IOL com reposição ou troca do implante primário gerou resultados cirúrgicos e visuais comparáveis.


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Migração do Implante de Lente Intraocular/cirurgia , Implante de Lente Intraocular/métodos , Lentes Intraoculares/efeitos adversos , Migração do Implante de Lente Intraocular/fisiopatologia , Implante de Lente Intraocular/efeitos adversos , Prontuários Médicos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Esclera/cirurgia , Fatores de Tempo , Resultado do Tratamento , Acuidade Visual , Vitrectomia/métodos , Corpo Vítreo/cirurgia
2.
Clinics ; 70(1): 34-40, 1/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-735858

RESUMO

OBJECTIVES: Acute ST-segment elevation myocardial infarction patients presenting persistent no-flow after wire insertion have a lower survival rate despite successful mechanical intervention. The neutrophil-to-lymphocyte ratio has been associated with increased mortality and worse clinical outcomes in ST-segment elevation myocardial infarction. We hypothesized that an elevated neutrophil-to-lymphocyte ratio would also be associated with a persistent Thrombolysis In Myocardial Infarction flow grade of 0 after wire insertion in patients undergoing primary percutaneous coronary intervention. METHODS: A total of 644 patients with ST-segment elevation myocardial infarction who underwent primary percutaneous coronary intervention within 12 hours of symptom onset were included in our study. Blood samples were drawn immediately upon hospital admission. The patients were divided into 3 groups according to their Thrombolysis In Myocardial Infarction flow grade: Thrombolysis In Myocardial Infarction flow grade 0 after wire insertion, Thrombolysis In Myocardial Infarction flow grade 1-3 after wire insertion and Thrombolysis In Myocardial Infarction flow grade 1-3 at baseline. RESULTS: The neutrophil-to-lymphocyte ratio was significantly higher in the group with Thrombolysis In Myocardial Infarction flow grade 0 after wire insertion compared with the group with Thrombolysis In Myocardial Infarction flow grade 1-3 after wire insertion and the group with Thrombolysis In Myocardial Infarction flow grade 1-3 at baseline. The group with Thrombolysis In Myocardial Infarction flow grade 0 after wire insertion also had a significantly higher in-hospital mortality rate. Persistent coronary no-flow after wire insertion was independently associated with the neutrophil-to-lymphocyte ratio. CONCLUSIONS: An increased neutrophil-to-lymphocyte ratio on admission is significantly associated with persistent coronary no-flow after wire insertion in patients with ST-segment ...


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Linfócitos , Infarto do Miocárdio/cirurgia , Neutrófilos , Fenômeno de não Refluxo/sangue , Intervenção Coronária Percutânea/métodos , Terapia Trombolítica/métodos , Biomarcadores , Circulação Coronária/fisiologia , Métodos Epidemiológicos , Mortalidade Hospitalar , Infarto do Miocárdio/mortalidade , Fenômeno de não Refluxo/diagnóstico , Prognóstico , Intervenção Coronária Percutânea/mortalidade , Valores de Referência , Fatores de Tempo , Resultado do Tratamento , Terapia Trombolítica/mortalidade
4.
Clinics ; 65(10): 979-984, 2010. tab
Artigo em Inglês | LILACS | ID: lil-565981

RESUMO

PURPOSE: To analyze the effect of maintenance hemodialysis on left ventricular diastolic function in patients with end-stage renal disease. METHODS: Study population consisted of 42 patients with end-stage renal disease. Before an arteriovenous fistula was surgically created, the patients were evaluated by conventional and Doppler echocardiography and Doppler tissue imaging. Then, the patients undergoing hemodialysis treatment when the arteriovenous fistula was compleated. After the first hemodialysis session (mean 76.14 ± 11.37 days) the second echocardiographic evaluations were performed. RESULTS: Mean age was 58 ± 13 years and 21 ( percent50) of the patients were female. After maintenance hemodialysis treatment; peak early (E) and peak late (A) diastolic mitral inflow velocities and E/A ratio were not significantly change however the deceleration time of E wave and left atrial diameter were significantly increased. Also there was no change in the early (Em) and late (Am) diastolic myocardial velocities and Em/Am ratios of lateral and septal walls of left ventricular. E/Em ratio was decreased insignificantly. Pulmonary vein velocities and right ventricular functions are remained almost unchanged after hemodialysis treatment. DISCUSSION: The acute and long-term effect of hemodialysis on left ventricular diastolic function is unclearly. Patients with end-stage renal disease treatment with hemodialysis via arteriovenous fistula experience a variety of hemodynamic and metabolic abnormalities that predispose to alterations in left and right ventricular functions. The present study showed that left ventricular diastolic function except left atrial diameter and right ventricular functions were not significantly change, however left ventricular systolic functions were impaired after maintenance hemodialysis treatment in patients with end-stage renal disease. CONCLUSION: It has been suggested that echocardiographic parameters are useful markers for evaluation of left ventricular and right ventricular functions in patients with end-stage renal disease. However, in patients with endstage renal disease treated with hemodialysis, repeated assessment of echocardiographic examinations to observe serial changes in left and right ventricular functions are not yet well established. In this study, we showed that acute changes of volume status and electrolytes and autonomic regulation by hemodialysis session did not affect left ventricular diastolic and right ventricular functions in a relatively long term.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Diástole/fisiologia , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/fisiologia , Derivação Arteriovenosa Cirúrgica , Ecocardiografia Doppler , Falência Renal Crônica/complicações , Falência Renal Crônica/fisiopatologia , Estudos Prospectivos , Diálise Renal/métodos , Estatísticas não Paramétricas , Fatores de Tempo , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA